Monday 27 January 2014

The Future of Power

Kevin Arthur, CEO of Oxford Photovoltaics

It took just 10 minutes for Kevin Arthur to be persuaded that the tiny square of red glass on his fingertips was the future of solar power.
He had only recently been involved in a solar energy start-up company and was keen to try his hand at something new.
We would still be in the lab if it wasn't for the Technology Strategy Board – they listened to us when nobody else would – and their faith in our technology is seeing fruition right now – we are world leaders in our field - Kevin Arthur, CEO of Oxford Photovoltaics
 
But that was before he met the charismatic Oxford Universityphysicist Dr Henry Snaith and saw his remarkable solar cells.
 
‘I went into the room a sceptic and came out a believer,' says Kevin, the Chief Executive Officer of Oxford Photovoltaics.
We have been on the most amazing journey with them [Technology Strategy Board] - Kevin Arthur
 
Four years later – with a range of Technology Strategy Board fundings under their belt the two of them were heading up one of the UK's most promising young green electrical companies.

The incredible journey

scientist working in a laboratory
‘We would still be in the lab if it wasn't for the Technology Strategy Board – they listened to us when nobody else would – and their faith in our technology is seeing fruition right now – we are world leaders in our field,' added Kevin.
 
‘We have been on the most amazing journey with them. In the beginning – on that day in that room just four years ago – Henry showed me a solar cell technology that was low-cost, easy to produce and which could be printed on the surface of glass. 
 
‘The idea gripped me straight away. You mixed up the stuff and printed it on glass. That meant it could be used in the glass skins of commercial buildings - a massive market. I was really excited by the opportunity!'
Unlike conventional silicon solar panels which use rare earth metals and toxic materials, Henry's photovoltaic cells, developed at the Photovoltaic and Optoelectronic Device Group in Oxford University's Physics Department, use cheap, abundant and environmentally friendly materials - Kevin Arthur
 
By November 2009, Kevin already had more than 20 years' experience in the semi-conductor industry and two promising university spin-outs under his belt. He wanted a new challenge. 
 
needle and microscope
‘I was entrepreneur in residence at Imperial College when I was phoned by Isis Innovation – Oxford University's technology transfer arm - who asked if I wanted to be chief executive officer of another solar start up.
 
‘I'd already done solar with a university spin-out called QuantaSol so I told them ‘no thanks,' but by the end of that meeting with Henry  I had changed my mind,' explained Kevin. 
 

Low cost solutions for the environment

‘Unlike conventional silicon solar panels which use rare earth metals and toxic materials, Henry's photovoltaic cells, developed at the Photovoltaic and Optoelectronic Device Group in Oxford University's Physics Department, use cheap, abundant and environmentally friendly materials.
 
‘The technology works by printing a microscopic layer of ‘solid-state dye sensitised solar cells' on ordinary glass. The cells are sealed with a thin layer of glass.
 
‘A layer of cells is just one or two thousandths of a millimetre thick (one or two microns) and can be made in a range of colours and transparencies,' said Kevin.
 
‘In contrast, the equivalent traditional product – amorphous silicon solar cells often found in calculators – are black or brown and the process of making them transparent severely reduces their already low efficiency. 
scientists in a laboratory
 
‘These new solar cells are more efficient, more stable, thinner and use lower cost materials,' says Kevin. ‘They make beautifully clear coloured glass,' he added.
 
‘They work at much higher temperatures than existing technology which tends to lose efficiency above 25ÂșC. They also work well with diffuse light – making them suitable for building facades.
 

Harnessing the power of the sun

‘In 2009, the cells were working at five per cent efficiency, which meant it was converting five per cent of sunlight into electricity.
 
‘That isn't enough for a commercial product which typically works at 15 to 20 per cent efficiency but it was more than enough to show me that the invention had potential. I was hooked,' said Kevin.
All we could think was ‘Amazing! In one step, the Technology Strategy Board has got our company up and running! We could hardly believe it was true! - Kevin Arthur
 
He spent 11 months working on a business plan to allow Oxford Photovoltaics to licence the technology to glass manufacturers and processors. But money was hard to find and the company needed cash before Isis would release the patents.
 
Then in September 2010, Kevin learnt about Innovate 10 Launch Pad – a business competition run by the Technology Strategy Board for ‘disruptive' inventions and business ideas.
 
The prize was £25k and the chance to pitch for an additional £75k in front of 2,000 people at the Design Centre, Glasgow.
 
There was one catch. Kevin discovered this potential funding source late in the day and the deadline for submitting his video entry was noon the next day.
 
Kevin Arthur, Chief Executive Officer of Oxford Photovoltaics
‘To make it worse I had a board meeting at 10am. The whole thing is a bit of a blur now. But on that fateful day, I got up at 4.30am, found my video camera, got a tripod from the loft and wrote a two minute script which I stuck to the back of the office door at home.
 
‘Time was ticking, I was on my own and I'd never edited a video before. But I did it and it's still on YouTube. It looks pretty reasonable.
 
‘We got the initial £25k prize in the Energy category and then we had this chance to increase it to £100k at the event itself where we did a short presentation. We beat three other guys and suddenly we had the money to build the company.
 

One step to success with the Technology Strategy Board

If we hadn't got the £100k from the Technology Strategy Board we wouldn't have been able to licence the patents and we wouldn't be here now. But we did. They did - Kevin Arthur
 
‘All we could think was ‘Amazing! In one step The Technology Strategy Board has got our company up and running! We could hardly believe it was true!
 
‘If we hadn't got the £100k from the Technology Strategy Board we wouldn't have been able to licence the patents and we wouldn't be here now. But we did. They did.
 
‘The next day we hit the road and we started pitching to anybody who would listen,' said Kevin.
Once again, the Technology Strategy Board helped us realise our dreams, this time with a £250k grant under the Smart scheme - Kevin Arthur
 
The company took control of the patents, landed £700k from the clean technology investment specialists MTI Ventures and a syndicate of Angel investors and moved to Begbroke Science Park near Oxford in April 2011.
 
Now they faced a new challenge - to go from creating small prototypes to A4 panes of solar power glazing.
That £250k was extremely important because it extended the range of the funding we brought in, and kept us focused on tight timescales and milestones. It gave us more runway - Kevin Arthur
To do that they needed to build the company's research and development capacity. ‘Once again, the Technology Strategy Board helped us realise our dreams, this time with a £250k grant under the Smart scheme.
 
‘That £250k was extremely important because it extended the range of the funding we brought in, and kept us focused on tight timescales and milestones. It gave us more runway,' explained Kevin.
It is yet another British company that is at the forefront of technologies that just a few years ago we would have thought impossible -Kevin Arthur
 
Since then the investment has kept coming. By July 2013, Oxford PV and its 14 employers had secured £4.2m in funding, including an award from the European Commission Seventh Framework Programme for Research.
 
By summer 2013, an improved version of the cell achieved more than 15 per cent efficiency, a level similar to commercial products.
 

‘The technology at our fingertips to change the world'

It's taken less than four years for Oxford PV to go from the lab to one of the UK's most promising green companies, and we did it with the Technology Strategy Board behind us who not only helped us financially but gave us the credibility for other, future investments - Kevin Arthur
 
The first revenues are expected by 2016 while the first office blocks that generate electricity from their windows could follow a few years after that. ‘Imagine that. And it is yet another British company that is at the forefront of technologies that just a few years ago we would have thought impossible,' said Kevin.
 
‘We think the added cost of doing this is 10 per cent on top of the cost of the glass. But this technology pays for itself in less than 10 years,' he added.
Kevin Arthur with a small solar panel
 
‘It's taken less than four years for Oxford PV to go from the lab to one of the UK's most promising green companies, and we did it with the Technology Strategy Board behind us who not only helped us financially but gave us the credibility for other, future investments." 
 
‘Henry believes that we have the technology at our fingertips to change the world – and we're determined to prove that he's right.'
 

Tuesday 7 January 2014

ELECTRICAL APPRENTICESHIP UK


I’ve just enrolled on a three-year course to become an electrician. It’s a complete career change, but after being made redundant four times from the engineering sector, I want a job that is “recession-proof”. However, because I now attend college during the week, I’m only available to work part-time. I’m worried this could put recruiters off from hiring me. Am I doing the right thing? Steven, 58, via email
You’ve certainly taken a bold step, Steven. Throwing your own money and time into a three-year course is not easy and demonstrates your commitment to changing careers. To some extent, your reasons for wanting to become an electrician are sound: businesses and home owners will always need electricians.
A word of caution though. The industry is far from “recession proof”. As construction and manufacturing projects have been scaled back over the last few years, so too has the need for all the trades associated with them – and electricians have suffered. David Marshall, of Electrical Recruitment Specialists, says he receives up to 150 applications for jobs. And all of them are from qualified electricians, with endless contact books and experience. When you qualify, you’ll be competing against them.
Which is why, if you’re serious about a career as an electrician, you must spend the next three years learning the trade, working in the trade, and building contacts in the trade. There is absolutely no point getting your course while working in a totally unrelated job – even if it’s something technical like engineering, Marshall says. Employers will want to see you’ve learned the ropes during your three years. That means rolling your sleeves up and getting out on site, just as much as it does turning up to class.
First things first though, Steven. Make sure your course is industry-recognised. I’ve done a bit of digging around for you, and to be taken seriously you must be on a City & Guilds course. If you’re not, change this now. If you are, you should be aiming – eventually – for an Electrotechnical Certification Scheme competence card, a “pass” which allows you to work at any industrial or domestic site. Check the sector’s skills council, Summit Skills, to make sure you’re on the right course at www.summitskills.org.uk.
Your next step is to try and secure work in the field. But as Matt Darville, an engineer at electrical contractors’ body the NICEIC, says: “Offering to do jobs for virtually nothing is a good start.” Electricians start as “labourers”, or “mates”, for about £10 an hour. The next level is called an “improver”, at about £11. They work with electricians, handing him or her cables, knocking down walls, talking to clients – everything except the actual wiring. Without these skills, employers are unlikely to consider you when you become qualified. You have to prove you can get stuck in, stomach long periods outside in the rain, or up a pole if need be. The contacts and job opportunities you’ll get from doing this are potentially huge. The Electrical Contractors’ Association website, www.eca.co.uk, lists the employers with these types of jobs available. Iain Macdonald, of the ECA, urges you to get your pitch right before approaching them, though. If you’re willing, state that you can work at a beginners’ rates, or firms may assume someone like you is too expensive.

Sunday 22 December 2013

WES Electrical Westend Glasgow


Westend Glasgow Electricians employ three full-time electricians.

Between them they have over 50 years experience in all aspects of electrical works including Domestic Housing, Commercial and Industrial.


Each of our electricians are:



Fully qualified to 17th edition Regulations

Fully qualified to City and Guilds 2391 Inspection, Testing and Certification


 At Westend Glasgow Electricians we have a well deserved reputation for being dependable, professional, reliable, and for carrying out all works to a high standard of quality at a very reasonable price.

DOMESTIC HOUSING

In order to give a top quality service we make sure to carry a stock of the most commonly requested items on our vans. This ensures that if the work we are asked to carry out is one of the most common things, for example changing a light fitting, or a light switch or socket, or adding additional sockets, we do not have to spend time going away to an electrical supplier to collect these items. This keeps the cost of the work down and enables us to provide an excellent service at a very reasonable price.For smaller works we are usually able to attend your home at a time of your choosing and advise on the best way of carrying out the work in the most cost effective manner. We will be able to give you a price there and then, and if you are happy with the price we can carry out the work straight away. This saves having to make a second visit and helps to keep the cost to a minimum.

Our electricians always make sure to keep disruption to a minimum while carrying out the works, and on completion carry out a thorough clean-up.



Westend Glasgow Electricians carry out all aspects of electrical works to Domestic Housing ranging from a Full Rewire to changing Plug Sockets and Lights.

  

At Wes electrical all quotes are given free of charge and at no obligation.

Monday 9 December 2013

FUSE BOARD INSTALLATIONS GLASGOW

changing a fusebox


FUSE BOARD CHANGING call 01418405236

Westend glasgow electricians

Fuse Board Changing by Westend Glasgow Electricians
The electrical fuse board is the brain that controls all the wiring in your property with every circuit carrying electrical current in your building leading back to this one single place. Many properties are still operating on fuse boards and electrical wiring that were installed in the 1960s. These ageing installations are functional, but fall far short of modern safety standards. If your fuses keep breaking it could be that now is the time to think about changing your old fuse board for a modern one that offers better protection.
Westend Glasgow Electricians are a team of professional and qualified electricians operating all over west end glasgow, so, if you are looking for an electrician in Glasgow, Lambeth or Croydon for example, then we are perfectly placed to help. In addition to fuse board changes, our services cover anything electrical from simply adding an extra plug socket, to a full-scale rewire. Every job we do works to make the electrical circuitry in your property safer, and follows the strict guidelines laid down by the BS7671 Wiring Regulations (17th Amendment 1, 2011). Changing your fuse board is a significant step towards bringing electrical safety in your home closer to meeting these standards.
Modern fuse boards are fitted with RCDs, or Residual Current Devices, and MCBs, or Micro Circuit Breakers. These efficient devices are designed to detect faults in your circuits, and cut the current in an instant should anything unusual be identified. Significantly reducing the risk of electric shock and the sparks or overheating that can cause electrical fires, these modern circuit breakers offer great peace of mind.
Also known as a fuse box, consumer unit or consumer board, the fuse board in your property needs to be equipped to cope with the demands of modern household appliances. Taken together, things like fridges, electric kettles, washing machines and dishwashers are much more power-hungry than anything that was around when the old fuse boards were first installed. Your new fuse board will be fitted with sufficient breakers to cope with these elevated power demands within your property, with each circuit being protected more effectively than ever before.
Fuse board changing is a relatively straightforward task that can generally be done within a few hours depending on the number of circuits in your property, and the complexity of the wiring currently in place. The change can only legally be effected by a qualified electrician who is Part P registered.  It is necessary when changing a fuse board to ensure that the earth-bonding arrangements in your property meet current standards, and are upgraded if required. The fuse board replacement cost will vary according to your requirements, but is not as expensive as you may imagine, and it’s a small price to pay for your security.
At Westend glasgow Electricians we have been providing electrical services to domestic and commercial clients in South London for over 20 years. Customers looking for an Emergency Electrician in partick, a fuse board change in Bromley, or a new plug socket in glasgow know that engaging the services of our team of experts will deliver fast, efficient and professional results, every time.

DIY DANGERS

There are so many programmes and articles on how to D.I.Y and sometimes, it is easier to watch a YouTube video and have a go yourself. Some jobs however are better left to the professionals. Especially with electrics where you can be seriously harmed if something goes wrong.
One of the biggest dangers of doing DIY electrical work is the electricity itself. We are so used to pressing buttons or flipping a switch we forget how powerful it can be. The slightest mistake like using the wrong tools, brushing a wire against another or forgetting to turn of the power, can lead to anything from electric burns to death. While you may be fine Googling how to change a fuse, it is always better to contact reliable and cost effective professionals like Westend Glasgow Electricians, to ensure no avoidable accidents occur.
Professionals at Westend Glasgow Electricians know exactly how to test circuits and find out where problems are coming from. This can be more difficult in older houses with dodgy wiring and the labelling on the fuse box has faded. Not only are you creating hazards when you carry out electric work yourself, you may not be meeting regulations. This could lead to a lot more problems like invalidating any home insurance if the problem was caused by work not following standards. By using a qualified and registered electrician, you can rest assured they are covered by their insurance and will carry out the job professionally and can be held accountable.
If you’re in doubt, it is always better to use a professional so call west end glasgow Electricians today to get free advice.

Sunday 3 November 2013

Kitchen fitter in Westend Glasgow


WESTFIELD KITCHENS BRINGS TO YOU AN OVERVIEW OF FITTING A KITCHEN IN WESTEND GLASGOW.


WE ARE PROFESSIONAL KITCHEN FITTERS FEEL FREE TO VISIT OUR WEBSITE FOR MORE INFO www.westfieldkitchens.co.uk

If you are planning to fit your own kitchen then just follow our step-by-step guides and instructions to help you on your way. We have included photos to assist the DIYer and to give you a better understanding on how your stunning new kitchen can be built.
Not only will you save hundreds of pounds by fitting a kitchen yourself, but you will also have a great sense of pride once it has been fitted.
Fitting a New Kitchen

FITTING A NEW KITCHEN – 1 What you need

To completely fit a new kitchen you need to be a competent DIYer, with good skills in carpentry and a good knowledge of electrical and plumbing work. If some of the work needs to be carried out by a plumber, (Gas Safe registered for gas work) joiner or an electrician then these are costs that need to be considered. Even with these costs you can save a lot of money fitting the kitchen units yourself. I was recently quoted around £1500 to fit a basic kitchen and the quote excluded plumbing and electrical work so there are great savings to be made with DIY.


Fitting a new kitchen isn’t a ‘two minute job’ and requires a lot of tools :-
Battery drill / driver plus wood and masonry drill bits, electricians screwdrivers, power / pipe detector, claw / lump hammers, bolster chisel, spirit level, pliers, side cutters, pump pliers, saw, Jigsaw, tape measure, sealant gun, square, marker pens.
Don’t forget safety equipment such as goggles, face mask and gloves. If you are using 240volt power tools use an RCD protection device.
Always remember Safety comes First, check before starting work where the services are in the kitchen, use a power / pipe detector to check for hidden live cables and water / gas pipes before removing the old kitchen units, drilling holes or chasing out walls.

FITTING A NEW KITCHEN WESTEND GLASGOW – 2 Plan the layout

To plan your new kitchen layout start by taking measurements of the kitchen area, when you have finished it is worthwhile double checking your measurements to save a lot of future problems.
These are some points to consider with your layout :-
The sink unit is usually positioned under a window.
Sink units and hobs should not be positioned too near or on a joint in a worktop.
Washing machines and dishwashers should ideally be positioned near the sink as this will reduce the amount of plumbing required.
Hobs require space on either side for pan handles.
Extraction units should be installed either near, or preferably on, an outside wall.
Don’t ‘box in’ any gas appliances as they require good airflow for correct operation and safety.
Are the existing services in suitable positions for your new kitchen layout, i.e. sockets and switches should not be positioned above hobs or cookers.
Will the new kitchen be user friendly and practical.
Wall units and the base units below them, should where possible, be the same width, so doors and handles line up.
Sockets should be around 150mm from the finished worktop to allow room for the plug top flex, they can of course go higher, if you know the size of tiles you are going to use, it is in my opinion easier to tile if the socket(s) are on the tile line.
Before you carry out any electrical work in the home check out the building regulations on the Government or local authority website specifically the Part P regulations  and Electrical safety in the home. Although I am aware of the current rules it is worth reading the latest regulations as they have been updated in the past.
Any gas work will require a Gas Safe registered  plumber / engineer.
When you have made a list of the units required for the kitchen don’t forget all the extras such as cornice, pelmet, plinth, corner post, jointing kit with coloured jointing compound, water waste kit, decorative clad end panels to match the doors, including maybe an extra one to use for filling any gaps, any appliance doors, etc.

FITTING A NEW KITCHEN WESTEND GLASGOW – 3 Preparation

The first step towards fitting your new kitchen is removing the old one. Wear the appropriate safety equipment, gloves, goggles, etc.
Remove all the doors, drawers and shelves first, then remove any screws that are fixing the worktop(s) to the base units. If the worktop edges are under tiles you may have to remove some, if not all of them to ‘free up’ the worktop. Some old kitchens have the worktop glued to the base units so the only removal solution may be a lump hammer and crowbar.
The units themselves should be relatively easy to remove and come apart fairly easily, especially with ones trusty lump hammer, but watch out for hidden cables and pipes, an indoor pool is not always appreciated. Once the water is turned off, the pipes cut and the sink unit removed, it is a good idea to fit in-line / gate valves to the remaining pipes, at least this enables the water to be turned back on, and fitting new pipework should hopefully not have to interrupt the water supply. Try and get some assistance when removing the wall units as they may be heavy or simply awkward to handle by yourself.
If you are disconnecting any electrical supplies, switch off the consumer unit and remove the fuse / miniature circuit breaker as well, this reduces the chance of the circuit becoming ‘live’ if the consumer unit is switched back on by accident, double check the supply is ‘dead’ at the point of disconnection, if in doubt use the services of a qualified electrician as electric shocks can be fatal. Don’t attempt to disconnect any gas supplies, the law says this can only be carried out by a Gas Safe registered  plumber / engineer.
So now the kitchen area is cleared, any repairs to existing walls and floors can be carried out. Holes in walls for air extraction and waste pipes can drilled / knocked through, electrics and plumbing can be installed to suit your new kitchen, don’t forget electrical supplies for wall unit lighting and the extract fan if they aren’t already in position, usually when an oven and separate hob is installed the oven comes fitted with a 13amp plug top and may require the installation of an extra socket outlet, the electric hob is then connected to the cooker switch, as this can have a much higher current demand.

FITTING A NEW KITCHEN WESTEND GLASGOW – 4 Where to start


Your new kitchen units have been delivered and the kitchen area is ready for the install, but where do you start ?. The first job to do is check the level of the floor, wherever the highest point is measure up 870mm and mark the wall, this measurement allows 720mm for the base unit and 150mm for the plinth. From your mark draw a level line using your spirit level across the wall(s), this is the guideline for all your base units, now measure up from the 870mm mark to the bottom of your wall units (this measurement is down to personal preference) , I would suggest 400 – 440mm, from this mark draw a level line across the wall(s), and finally measure up from the mark to the top of the wall units i.e. 720mm, and once more draw a level line across the wall(s). Now double check your lines are all level.
Create a space where the units can be assembled, some of the unit flat-packs can be very heavy, so get assistance when lifting them, use the cardboard packaging to cover the floor to stop the units from getting scratched, and keep all the hinges and coloured blanks in a box for later. Assembling the first unit using the instructions can take a while, but once you have an assembly method the rest will go together quite quickly. If you are using a battery drill / driver without torque control take care not to over tighten screws, it is sometimes safer to use a screwdriver for the last one or two turns.
If your kitchen is in a ‘L’ or ‘U’ shape start fitting the units from the corner working out in both directions. Before fixing the wall units I prefer to place the first base unit levelled up and in position, then I mark the wall with a vertical line from its edge so I have guideline for the wall units so they will line up with the base units. Wall units usually come with two fixing brackets each, when you have assembled the wall unit, measure where the fixing brackets need to be in order for it to ‘hook on’, transfer the measurements to your wall and fix the brackets securely, I normally drill the fixing(s) at a slightly downward angle as this reduces the chance of the fixing ‘pulling out’. Use good quality fixings and in the case of plasterboard, use cavity fixings where the brackets don’t land on a wall stud. For peace of mind on a plasterboard wall I always fit additional angle brackets between the wall studs and the top of the wall unit so I know I have a good fixing, they may be a little unsightly but they are usually out of sight and can be painted or papered over, at least you know the wall unit won’t become a base unit overnight !. Mount each wall unit checking them with a spirit level and making sure the edges are flush as you go along, they are adjustable via two screws inside either top corner of the wall unit, one screw raises or lowers the unit, the other pulls the unit tight against the fixing bracket and locks it in position. At this stage don’t worry about any small gaps between the wall unit end and the wall itself.
As I explained earlier in this post, start installing the base units from the corner ( if you have one ), make sure each unit is level before moving onto the next one, use your 870mm level line as the guide, The sink base unit will of course require holes drilling to allow the water / waste pipes through to the bottom of the sink unit, Don’t fix the units to the wall until they are all in position and you are sure they are all level. Most flat-pack kitchen units come with two male / female bolts that can be fitted between each unit, these usually require a hole drilling of approximately 5mm dia through the sides of the units, but when fitted hold the units together and keep the edges flush ( drill new holes for the bolts, don’t be tempted to use existing ones as they may be for drawer runners, etc ).

FITTING A NEW KITCHEN WESTEND GLASGOW – 5 Worktops

I am assuming for the purpose of this post that you will be using joint strips between the worktop edges, you can of course cut a mitre joint using a router and jig but this is a task where I would use the services of a skilled joiner, these cuts have to be precise and the cost, not forgetting the wait for a replacement worktop, has in the past put me off having a go. If you are skilled and confident enough to cut a mitre joint, check first that your router has a collet big enough to take an half inch (13mm) router bit, as the ‘bits’ which cut to worktop depth usually as far as I am aware have an half inch (13mm) shank, whereas most DIY routers will only take up to an 8mm shank. Butt joints (worktops joining edge to edge) are easier but have to be cut accurately, on the reverse side of the worktop(s), slots have to be cut-out using a router and jig, clamping brackets which sit in these slots are then tightened from below when the worktop is in position on top of the kitchen units.
Worktop jointing clamps
Worktop jointing clamps
Coloured joint sealant and solvent
Coloured joint sealant and solvent







Try not to have the joint too near any of  the ends of the base units as the clamps may be difficult to gain access to and tighten up. Coloured jointing sealant should be put onto one edge of the two sections of worktop and as you tighten the clamps check constantly how flush the worktop edges are simply by touch, take care not to over-tighten the clamps as the finished edge of the worktop might start to ‘lift’ . When you are satisfied with the quality of the joint, clean away surplus joint sealant with the solvent that should be supplied with it. Incidentally the coloured sealant is very handy to mask any small chips or scratches that may unfortunately occur during the fitting of the worktop(s).
  • Fitting kitchen worktops requires assistance, not only for cutting them to length, but also because of their size and weight, the last thing you want to do is to damage one when placing it on top of the new kitchen units. If you have a ‘U’ or ‘L’ shaped kitchen start with the centre or ‘back’ worktop. Before you cut the worktop to length measure along both the back and front edges of your base units just in case the walls are not quite square and transfer these measurements to your worktop. Double check your measurements and remember you can allow a few millimetres for any end that will have wall tiles overlapping the worktop edge, then do the cut, this can be done using a woodsaw, but a jigsaw certainly makes the task easier, just remember to use goggles and a face mask, if you can’t see your cutting mark on the worktop use masking tape and re-mark the cutting line. When positioning the worktops on the base units you may have to chase out a bit of plaster along the wall to allow the worktop front edge to line up with the base units, ideally the worktop should extend over the base units front edge by an equal amount along its whole length.
  • Now measure the other worktop(s) again, across both the front and back edges of the base units and cut to size allowing for the joint strip. Seal the end of the worktop with either pva glue or clear sealant before fitting the joint strip to stop any future liquid spillage from damaging the worktop. When you are satisfied the worktop(s) are sitting on the base units correctly you can mark out your cuts for the sink unit and hob, once again use masking tape if you cannot see your marking out clearly. If you are fortunate the sink unit and hob will come with templates to mark the worktop for cutting out. Generally the hole to be cut is around 5 – 10mm less than the circumference of the sink unit or the hob. The sink unit can be placed face down on the worktop, the circumference can be marked out, then reduce this cut by the appropriate measurement all round. The hob may have no template but should have the cut out dimensions supplied with it, these dimensions need to be marked out very accurately and make sure the hob is in the position you want it . Double check your measurements before making any cuts in the worktop (I fitted a hob recently which only had a 5mm edge that rested on the worktop so I must have checked my marking out at least several times). These cuts can then be made using a jigsaw. When you have completed the cuts and the worktop(s) are back in position they can be fixed using the screws supplied with the base units. Again seal the cut-outs of the worktops with pva glue or clear sealant prior to fitting the sink unit and hob.


  • FITTING A NEW KITCHEN – 6 Finishing the project
  • Fitting the hob and sink unit is fairly straightforward, both come with clips that hold them down tightly to the worktop. Hobs usually have a thin foam or rubber seal around the edge and this is sufficient to keep any liquids out. Only you know whether you are competent enough to reconnect the hob to the electrical supply. I would recommend you use a qualified electrician who will use the correct size / type of cable and connect the hob correctly for safe use. With gas hobs you should use a Gas safe registered  plumber / engineer to connect the hob to the gas supply.
  • Before fitting the sink unit, if possible fit the tap(s) with two flexible water pipes to it, each around 30cm long (which will save a lot of time when reconnecting the pipework) and also run a bead of clear sealant approximately 6 – 8mm thick under the edge of the sink unit which should be more than adequate to keep out any liquid, then position the sink unit in place and tighten the clips until it is secure. Be careful not to over-tighten the clips as they tend to ping off and are difficult to refit. Remove any excess sealant from the outer edge of the sink unit. Now you can fit the waste pipework and finish plumbing in the water pipes to the tap. Now the plinths can be cut to length and fitted, they usually attach to the base unit legs via plastic clips that are fixed to the reverse side of the plinth. The cornice and pelmet can also be cut to length. Using a mitre saw power tool can give a very
  • Fixing blocks
  • Fixing blocks
  • good quality, clean cut and therefore a better finish, especially if any angled cuts are required. Don’t forget the goggles and face mask. You may want to wait before cutting the pelmet to length as any tiled walls could alter its required length. Both the cornice and pelmet can be fitted to the wall units using fixing blocks with of course the correct size screws. Wall unit lights can be fitted, but again you may wish to wait until any tiling has been completed.
  • So finally the drawers and doors can be fitted, drawers are relatively easy to assemble following the instructions. Attach one door at a time to the units, hinges are normally in two parts, one for the unit and one for the door. Fit the unit one(s) first so they are ready to accept the door. Now fit the other parts to the door.
  • Two part hinge
  • Two part hinge
  • Handles both for the doors and drawers may require two fixing holes being drilled, there are dimple marks on the reverse of the doors to indicate where to drill the holes, these holes should be drilled as straight as possible and with the correct size drillbit to suit the fixing screws for the handles. When fitting the doors make sure the two parts of hinge mate together correctly otherwise it will be difficult to adjust the door. As you look at the hinge, the screw at the back holds the door in place, the other one enables you to adjust the door later for alignment. When all the doors are fitted they can be adjusted so gaps between them are even and all doors are level.
  • Chrome door handles
  • Chrome door handles
  • When finishing off the new kitchen its worth sealing any gaps at the back of the worktops with clear sealant so there is less risk of water damage before the wall(s) are tiled. Any small gaps between the kitchen units and the wall(s) can be filled using cuts of decorative clad end panel, doing this gives the kitchen a more professional finish. As shown in one of the images below I partly filled a gap between a washing machine and a wall using a piece of 75 x 15mm timber with cabinet magnets on the reverse for ease of removal, then simply tiled the timber using liquid nails as an adhesive, it was simple to do and  leaves a small gap for washing machine movement. The last job aside cleaning up and telling everyone how hard you have had to work like I do, is to blank any pre-drilled holes in the units with the plastic blanks / caps that come with the units.
  • Below are a selection of thumbnail images from a recent new kitchen install. They show before and after, etc.
  •  
  •  
  •  
  •  
  •  






Ensuring Safe Homes: The Imperative of Electrical Testing, Qualified Electricians, and EICRs for Landlords in Glasgow

https://g.co/kgs/Fsif6i Introduction Renting out a property comes with significant responsibilities, particularly when it comes to the safet...