Friday 27 May 2016

Certificates 4 Landlords - Smoke Alarms

Introduction


From the 1st October 2015 regulations require smoke alarms to be installed by qualified electricians in rented residential accommodation and carbon monoxide alarms in rooms with a solid fuel appliance. Changes are also made to the licence requirements in relation to houses in multiple occupation (HMOs), such as shared houses and bedsits which require a licence and also in relation to properties which are subject to selective licensing. The Regulations apply both to houses and flats. Failure to comply can lead to a civil penalty being imposed of up to £5,000.
These provisions only apply in England; not Wales.

Who is affected?

The requirements are imposed on the immediate landlord. There is an exemption for providers of social housing. A tenancy includes a licence to occupy a residential premises and it also extends to subletting for these purposes.
In the case of a licensed HMO or where there is a selective licensing it is the responsibility of the licence holder to ensure that mandatory conditions imposed in relation to the installation of alarms are complied with.

The premises affected

These duties apply to residential premises which means premises all or part of which comprise a dwelling. Thus, it will apply to a flat over a shop. If the property is a licensed HMO or subject to selective licensing there are mandatory conditions imposed on licences.
The premises must be let under a specified tenancy or a licence. This is a tenancy or licence of residential premises which grants one or more persons the right to occupy premises as their only or main residence. Rent or a licence fee must be payable.
There are various exemptions:-
  • A tenancy under which the occupier shares any accommodation with the landlord or a member of the landlord's family. There must be a sharing of an amenity which includes a toilet, personal washing facilities, a kitchen or a living room but excludes any reference to storage or access.
  • A tenancy which is a long lease or which grants a right of occupation of the premises, i.e. for more than 21 years.
  • Student halls of residence.
  • Hostels
  • Care homes
  • Hospitals
  • Accommodation relating to health care provision

Requirement for Smoke alarms

During any period beginning on or after 1st October 2015 while the premises are occupied under a tenancy (or licence) the landlord must ensure that a smoke alarm is equipped on each storey of the premises on which there is a room used wholly or partly as living accommodation. A living room will include a lounge dining room and kitchen as well as a bathroom or toilet. It also includes a hall or landing. This means that a smoke alarm must be provided in working order on each storey. The RLA takes the view that mezzanines are caught by this legislation where they contain a room used wholly or partly as living accommodation, including a bathroom or toilet. As regards individual flats located on one floor then there will have to be at least one alarm within the flat itself or alternatively are provided outside the flat on the same floor of the building, i.e. a communal alarm.
Likewise, for flats comprising more than one storey there will need to be a smoke alarm on each floor.
It is the location of an alarm which sounds which is crucial; not the positioning of detectors.
The Regulations do not stipulate what kind of alarm is required. Ideally it should be a hard wired alarm system. It can, however, be a single standalone alarm. Landlords are recommended by the RLA to fit ten year long life tamper proof alarms, otherwise there is a problem of batteries being taken out and not being replaced.
As a final note, heat detectors are not considered sufficient. It will have to be a smoke detector.

Carbon monoxide alarms

Additionally, landlords must ensure that there is a carbon monoxide alarm fitted in any room that is used partly or wholly as living accommodation which also contains any appliance which burns, or is capable of burning, solid fuel. This would include log and coal burning stoves and open fires, even if they are not normally in use, but does not include gas and oil boilers. If an open fireplace is purely decorative and not useable then it is not covered by the regulations.
Gas is not a solid fuel and so there is no requirement to fit one near a gas boiler. It is still advisable as best practice however.

Checks

The landlord is specifically required to carry out a check to ensure that smoke alarms or carbon monoxide alarms installed to comply with the Regulations are in proper working order on the day a tenancy begins where it is a new tenancy. A new tenancy is a tenancy granted on or after 1st October 2015.
For these purposes a new tenancy does not include a tenancy which was granted where the original agreement was entered into before 1st October 2015; nor does it include a periodic statutory tenancy which arises when a fixed term shorthold tenancy ends. It does not apply to a tenancy which starts at the end of an earlier tenancy where the landlord and tenant are the same as under the earlier tenancy and the premises are the same (or substantially the same) as those under the earlier tenancy. Therefore this express requirement to check does not apply to the renewal of a tenancy for the same premises by the same landlord to the same tenant. This should not be confused with the requirement to install detectors and alarms which applies to tenancies in existence before October 1st 2015.
In our view, landlords should not be under a false sense of security because of this provision. Our reading of the regulation is that there is an ongoing obligation to ensure that any smoke alarm or carbon monoxide alarm installed to meet these requirements is in working order. Alarms should therefore be checked periodically to see that they are working properly. There is no reason why this responsibility should not be placed on the tenant and the government guidance does suggest the tenant check monthly. However, the landlord will then have to make sure that the tenant does actually carry out the checks. If challenged, a landlord could have to show that a proper system has been put in place to check alarms regularly.

Placement of Alarms

The regulations do not tell landlords where to place the smoke alarms, instead the guidance suggests the landlord follow the manufacturer's instructions which will typically be at head height between 1-3 meters away from the solid fuel burning source for carbon monoxide alarms and in a circulation point for smoke detectors.

HMOs and Selectively licensed properties

As from 1st October 2015 new licence conditions will be included requiring the provision of smoke alarms and fire detectors. In the case of HMO licences they already contain provisions for alarms in any case. The regulations themselves are not applicable in this kind of accommodation.

Enforcement

The local authority is responsible for enforcement.
A local authority must serve a remedial notice within 21 days where they have reason to believe that the landlord is in breach of any of these duties relating to smoke alarms or carbon monoxide alarms. A remedial notice must specify the action to be taken within 28 days of the date of the service of the notice. It allows the landlord 28 days to make representations against the notice.
The landlord must then take the required action within the period allowed. There is an excuse for a landlord for non-compliance with the notice if the landlord can show that he has taken reasonable steps to comply with the duty, but the landlord is not required to take legal proceedings. This could cover a situation where the tenant refuses access to allow the work to be done.
If the landlord fails to take action then the local authority must, if it has the necessary consent to do so, arrange for the work required to be undertaken within 28 days of consent being obtained if consent of the occupier of the premises is required. Therefore if a local authority is also refused access by the tenant it cannot take the necessary steps itself.

Penalties

If the landlord is in breach the local authority may require the landlord to pay a penalty charge up to a maximum of £5,000. It has discretion whether or not to impose this charge. If it intends to impose a charge it must serve a penalty charge notice within six weeks from when it is first satisfied that a breach has occurred. A right to make representations against the penalty notice is given and the local authority may reduce the charge for prompt payment.

Appeals

If the local authority upholds a penalty charge notice there is a right to appeal for the landlord to the First Tier Tribunal. The Grounds of Appeal are:-
  • Local authority has made an error of fact or law
  • The amount of penalty charge is unreasonable
  • The decision to impose a penalty is unreasonable for any other reason
Payment of the penalty is suspended pending any appeal.

Local authority penalty policy

Each local authority must publish a statement of principles which will be followed in determining the amount of any penalty charge. This statement will be taken into account in deciding on an individual penalty for a particular case.

Monday 22 February 2016

A Guide To Central Heating Systems





A Guide To Central Heating Systems


There are three main types of gas central heating systems used in housing:
  • Combination Boiler Systems
  • Gravity Fed Systems
  • High Pressure Systems
All three of these systems heat central heating radiators in similar ways. The main differences are the water pressure that the boiler operates at and the way hot water is provided.
heating engineer Combination Boiler System
Often referred to as a ‘combi boiler’ this type of installation heats hot water as you need it, without the need for a hot water storage tank. So in places where space and hot water requirements are limited, such as flats, these can be very popular systems. The system uses mains water pressure, so there are no overflow tanks.
The major downside is the flow of hot water is slower than systems that provide stored hot water – most systems will struggle to cope with houses with two bathrooms. To have a reasonable level of hot water flow the boiler output has to be in a range of 25-30kW rather than 15-20kW for a system with a hot water storage tank. If you are thinking of using solar water heating in the future then another downside is that these systems are not suitable for use with a combi boiler as they need a hot water cylinder. Read more in our solar panels cost article.
See Combination Gas Boilers for a list of current popular combi boilers with typical consumer prices.
Gravity Fed Systems


Central Heating System Gravity Fed System

Historically a gravity fed central heating system was the most common system installed in UK housing. They are less common now as combi and high pressure systems are both superior when a complete new system is being installed.


Many older homes have existing gravity fed systems, so it may be more cost effective to upgrade the existing gravity fed system with a new more efficient boiler rather than go to the expense of a complete new system. Some manufacturers call boilers for a gravity system “open vent boilers”, “heat only boilers”, “conventional boilers” or “regular boilers”. Most system boilers can also be used with a gravity system. A system boiler has additional built in components such as a pump which makes installation easier than for a heat only boiler.
The major downsides are:
  • the water pressure for hot and cold taps can be quite poor, as the flow depends on gravity. In flats, where there is no opportunity to put the water tanks in a loft, shower water pressure can be poor unless a shower pump is used.
  • The extra requirement for a cold water storage tank and an expansion tanks. These tanks were often installed in lofts where they become vulnerable to frost damage resulting in water leaks.

High pressure systems


High Pressure Unvented System


This type of system operates at mains water pressure and uses a stored hot water system. So if it is lashings of hot water at a forceful pressure you are looking for then this is the system for you. EICR Certificate Glasgow
The main downside is that these high performance systems tend to be more expensive than the combi systems as you have the additional expense of a hot water tank. They also tend to require a higher skill level amongst installers, although as these systems become more common this is less of an issue. Some manufacturers call boilers for a high pressure system with a tank “system boilers” although some heat only boilers can also be used if additional external components such as pumps are added. electricians

Sunday 3 January 2016

WES Electrical Southside Glasgow


From 1st December 2015, private landlords are responsible for ensuring that an electrical safety inspection of their property is carried out by a registered electrician at least every five years.

The new legislation explained

As of 1st December 2015, under sections 13(4A) and 19B(4) of the Housing (Scotland) Act 2006, private landlords in Scotland will be required by law to ensure that their properties are electrically safe.
This covers:
  • Any installations in the property for the supply of electricity
  • Electrical fixtures and fittings
  • Any appliances provided by the landlord under the tenancy.
Landlords must be able to prove that all of the above are in a reasonable state of repair and in proper working order.

So what do landlords need to do?

Landlords are required to ensure that regular electrical safety inspections are carried out by a competent person, and that anything that fails to pass the inspection is replaced or repaired immediately.
As a minimum, an electrical safety inspection must be carried out:
  • Before a tenancy starts, and
  • During the tenancy, at intervals of no more than five years from the date of the previous inspection.
A copy of the most recent electrical safety inspection reports must be provided to both new and retained tenants.
The person who conducts the checks must be employed by a firm that is a member of an accredited registration scheme operated by a body recognised by the Scottish Government – this will usually mean that they are registered with NICEIC or a member firm of the Electrical Contractors’ Association of Scotland (SELECT).
Both the NICEIC and the Electrical Contractors' Association of Scotland (SELECT) provide online tools for finding local members.

Transitional Rules

the Scottish government guidelines details the transitional rules for the scheme.
  • It requires any new tenant to receive an EICR if they take up their tenancy after the 1st December 2015.
  • Any existing tenant to receive a copy of an EICR before the 1st December 2016 (unless their tenancy will end before that date).
  • If an EICR (or new installation certificate) is available for the property that was produced since 1st January 2012, this is still in its perceived 5 year lifecycle this is still valid (for 5 years from issue).  These do not need any PAT report.
  • Any EICR produced after 1st December 2015 will also need Appliance test reports.

What happens during the electrical safety inspection?

An electrical safety inspection has two parts:
  • An Electrical Installation Condition Report (EICR) – formerly known as a Periodic Inspection Report (PIR) – on the safety of the electrical installations, fixtures and fittings.
  • A Portable Appliance Test (PAT) on any portable appliances that you have provided by the landlord.
For the Electrical Installation Condition Report, the registered electrician will carry out checks of installations for the supply of electricity, electrical fittings (including but not limited to switches, sockets and light fittings) and fixed electrical equipment (including but not limited to boilers, panel and storage heaters and hard-wired smoke and fire detectors).
As a result, the electrician will produce an EICR document that highlights any problems using different classifications: code C1 indicating ‘danger present’, code C2 indicating ‘potentially dangerous’ and code FI indicating ‘further investigation required’. Any remedial work that is undertaken as a result of the inspection will then be recorded on a Minor Electrical Installation Works Certificate.

Wednesday 25 November 2015

Electricians new regulations (Scotland)


WES ELECTRICAL 01418405236





WESThe Institution of Engineering and Technology (IET) has announced the IET Wiring Regulations BS 7671:2008 incorporating Amendment No. 3:2015 will be available in January 2015 in both print and digital formats. The amended IET Wiring Regulations, which sets out the national standard for which all new and amended electrical installations are to comply, will feature a number of important new changes and will be available from the IET from 5 January 2015. This latest amendment, the third following Amendment No.1 which was published back in 2011 and Amendment No.2 in 2013, will be published as a new consolidated book.

The amended regulations will include changes to the electrical condition report section, new requirements for mobile and transportable electrical units and changes for the installation of luminaries and light fittings – bringing them in line with the latest international and European standards. The amended IET Wiring Regulations will also include the new Regulation 421.1.200. This regulation requires that within domestic (household) premises, consumer units and similar switchgear assemblies shall comply with BS EN 61439-3 and shall have their enclosure manufactured from non-combustible material, or enclosed in a cabinet or enclosure constructed of non-combustible material and complying with Regulation 132.12.

This has been developed to safeguard against the risk of fire that can be produced from the overheating of connections in consumer units. Geoff Cronshaw, chief electrical engineer at the IET said: “The amended IET Wiring Regulations BS 7671:2008 incorporating Amendment No. 3:2015 will set the electrical standards for those professionals working in the electrical, construction and built environment industries. It is paramount that, as an organisation, the IET continues to ensure that electrical standards are up-to-date and relevant to the ever evolving requirements of the UK’s electrical industry. “What’s more, it is essential that all electrical industry professionals familiarise themselves with the amended IET Wiring Regulations when they are published in January 2015, to ensure that the work they do is compliant and, most importantly, is carried out in a safe and appropriate manner.”

 The IET will be making the amended Wiring Regulations available from 5 January 2015, both in print and via a digital subscription; more information and pre-orders are available now at www.theiet.org/amend3-books-pr.

westend Glasgow electricians

Sunday 8 November 2015

ELECTRICAL INSTALLATION CONDITION REPORT (GLASGOW)

Electrical Condition Reports 

Faulty and old wiring is one of the main causes or electrical fires in the home in Glasgow. You can reduce the risk of a fire, and other electrical hazards such as electric shock by direct contact by checking the condition of your electrical wiring, switches, sockets, main consumer unit know as a fuse board and other accessories regularly.

How old is my electrical installation?

Signs that can help you tell the age of your electrical installation in your home include:
  • Fixed cables coated in usually black vulcanised rubber (stopped being used in the 1960s).
  • Fixed cables coated in lead or fabric sheath (used before the 1960s).
  • A fuse box with a wooden back, cast iron switches, or a mixture of fuse boxes (used before the 1960s).
  • Older round pin sockets (or light switches), braided flex hanging from ceiling roses, brown (or black) switches, or sockets mounted in or no skirting boards (used before the 1960s).
  • Light switches on the walls or in bathrooms (used before the 1960s).
However old your electrical installation is, it may get damaged and will suffer from wear and tear. So you should get an electrician to check its condition at least every 10 years or or every 3 years if your a landlord and now the new regulations states overtime you have a change of tenancy.

What is the aim of a condition report?

The five main aims of a Eicr condition report are:
  1. Record the results of the inspection and testing to make sure the electrical installation is safe to be used until the next inspection (following any work needed to make it safe)
  2. Find any damage and wear and tear that might affect safety, and report it
  3. Find any parts of the electrical installation that do not meet the IEE Wiring Regulations
  4. Help find anything that may cause electric shocks and high temperatures
  5. Provide and important record of the installation at the time of the inspection, and for inspection testing in the future.

 Types of condition report

 In general, there are two types of domestic electrical installation condition report:
  • Visual condition report - this does not include testing and is only suitable if the installation has been testing recently.
  • Periodic inspection reports - this is what we would normally recommend, as it tests the installation and would find any hidden damage.

Glasgow

Monday 12 October 2015

Metal Consumer Unit Regulation 2016 Amendment 3


Below is the new amendments for the 17th edition electrical installation regulations

Need an electrician in Glasgow? 

NEW NUMBERING SYSTEM

The Third amendment recognises UK only regulations and these are now identified by a new numbering system. Regulations with a .100 number are CENELEC requirements and those with a .200 number are specific
to the UK.


PART 2 - Definitions

Definitions have been expanded and modified, including the introduction of some new symbols. A list of abbreviations used in the Regulations has been added. The definition of ‘competent person’ has been removed and it has been replaced with ‘instructed person (electrically)’ and ‘skilled person (electrically)’. These changes have been reflected throughout the wiring regulations.

CHAPTER 41 - Protection against electric shock


There is now a requirement for RCD protection for socket-outlets up to
20A for all installations, however exceptions are permitted for:
a specific labelled or otherwise suitably identified socket-outlet provided for connection of a particular item of equipment, or
where, other than for an installation in a dwelling, a documented risk assessment determines that the RCD protection is not necessary
Maximum earth fault loop impedances given in tables 41.2, 41.3, 41.4 and 41.6 have been revised to take account of the Cmin factor. Cmin is the minimum voltage factor to take account of voltage variations depending on a number of considerations.

CHAPTER 42 - Protection against thermal effects

Due to the number of consumer unit fires reported within domestic premises, Regulation 421.1.201 (UK only) has been added and

requires consumer units and similar switchgear to have their enclosure manufactured from non-combustible material or be enclosed in a cabinet or enclosure constructed of non-combustible material and complying with Regulation 132.12.
Please note: This regulation will be implemented on 1st January 2016 to allow for manufacturers to ensure an adequate supply of suitable cabinets or enclosures is available.

CHAPTER 51 - Common rules

Section 551 concerning compliance with standards requires all equipment to be suitable for the nominal voltage and also requires certain information to be noted on the Electrical Installation Certificate.

CHAPTER 52 - Selection and erection of wiring systems

A new regulation 521.200 (UK only) has been included giving requirements for the methods of support of wiring systems in escape routes.
The regulations concerning selection and erection of wiring systems have been re-drafted. Reference to “under the supervision of a skilled or instructed person” has been removed.

CHAPTER 55 - Other Equipment


A new section 557 Auxiliary Circuits is included. All auxiliary circuits are
defined in Part 2.

SECTION 559 - Luminaires and lighting installation

Requirements for outdoor lighting installations and extra low voltage lighting installations have been moved to new Sections 714 and
715 respectively.


PART 7 - Special Installations or Locations Section 701 locations containing a bath or shower

There is now a requirement for RCD protection to be provided for: low voltage circuits serving the location
low voltage circuits passing through zones 1 and 2 not serving the location.
Appendix 3 - Time/current characteristics of overcurrent protective devices and RCDs
This includes changes in connection with maximum earth fault loop impedance to take account of the Cmin factor given in CLC/TR50480:2011.

APPENDIX 6 - Model forms for certification and reporting

The schedule of inspections (for new work only) has been replaced by examples of items requiring inspection during initial verifications (which must be appended to the Electrical Installation Certificate).
A small number of changes to the Electrical Installation Condition Report and associated notes have been made, including a requirement to carry out an inspection within an accessible roof space where electrical equipment is present in that roof space.
This summary is not a definitive guide to all the changes introduced by Amendment 3 and contractors will be required to demonstrate a full and comprehensive understanding of AMD 3 at their assessment visit. 

electricians in glasgow westend

Wednesday 27 August 2014

Glasgow westend Electrical Contractor




2014 has been a busy year so far, as we approach the end of august i have seen many more clients coming to us for our expertise in electrical rewiring commercial and domestic both are equally as busy at the moment and long may it continue. Some of out larger customers include businesses with Glasgow airport and larger shopping centres in and around Glasgow.



Another massive change to the electrical industry this year in the installation of commercial LED lighting in buildings and shopping centres, not only does it reduce the cost of the electricity bills for the client but the lamps last up to 10 x as long as regular lamps that have previously been installed.



also on the rise for our business is the installation of custom tv installation around the home, from simply putting the tv on the wall to a complete wall make over with various points av ports and speaker installations, we are a professional installation company for audio visual equipment and are the best in Glasgow at what we do feel free to get in touch if you have a query or if you require a quotation.

EICR Glasgow

Sunday 22 December 2013

WES Electrical Westend Glasgow


Westend Glasgow Electricians employ three full-time electricians.

Between them they have over 50 years experience in all aspects of electrical works including Domestic Housing, Commercial and Industrial.


Each of our electricians are:



Fully qualified to 17th edition Regulations

Fully qualified to City and Guilds 2391 Inspection, Testing and Certification


 At Westend Glasgow Electricians we have a well deserved reputation for being dependable, professional, reliable, and for carrying out all works to a high standard of quality at a very reasonable price.

DOMESTIC HOUSING

In order to give a top quality service we make sure to carry a stock of the most commonly requested items on our vans. This ensures that if the work we are asked to carry out is one of the most common things, for example changing a light fitting, or a light switch or socket, or adding additional sockets, we do not have to spend time going away to an electrical supplier to collect these items. This keeps the cost of the work down and enables us to provide an excellent service at a very reasonable price.For smaller works we are usually able to attend your home at a time of your choosing and advise on the best way of carrying out the work in the most cost effective manner. We will be able to give you a price there and then, and if you are happy with the price we can carry out the work straight away. This saves having to make a second visit and helps to keep the cost to a minimum.

Our electricians always make sure to keep disruption to a minimum while carrying out the works, and on completion carry out a thorough clean-up.



Westend Glasgow Electricians carry out all aspects of electrical works to Domestic Housing ranging from a Full Rewire to changing Plug Sockets and Lights.

  

At Wes electrical all quotes are given free of charge and at no obligation.

Monday 9 December 2013

FUSE BOARD INSTALLATIONS GLASGOW

changing a fusebox


FUSE BOARD CHANGING call 01418405236

Westend glasgow electricians

Fuse Board Changing by Westend Glasgow Electricians
The electrical fuse board is the brain that controls all the wiring in your property with every circuit carrying electrical current in your building leading back to this one single place. Many properties are still operating on fuse boards and electrical wiring that were installed in the 1960s. These ageing installations are functional, but fall far short of modern safety standards. If your fuses keep breaking it could be that now is the time to think about changing your old fuse board for a modern one that offers better protection.
Westend Glasgow Electricians are a team of professional and qualified electricians operating all over west end glasgow, so, if you are looking for an electrician in Glasgow, Lambeth or Croydon for example, then we are perfectly placed to help. In addition to fuse board changes, our services cover anything electrical from simply adding an extra plug socket, to a full-scale rewire. Every job we do works to make the electrical circuitry in your property safer, and follows the strict guidelines laid down by the BS7671 Wiring Regulations (17th Amendment 1, 2011). Changing your fuse board is a significant step towards bringing electrical safety in your home closer to meeting these standards.
Modern fuse boards are fitted with RCDs, or Residual Current Devices, and MCBs, or Micro Circuit Breakers. These efficient devices are designed to detect faults in your circuits, and cut the current in an instant should anything unusual be identified. Significantly reducing the risk of electric shock and the sparks or overheating that can cause electrical fires, these modern circuit breakers offer great peace of mind.
Also known as a fuse box, consumer unit or consumer board, the fuse board in your property needs to be equipped to cope with the demands of modern household appliances. Taken together, things like fridges, electric kettles, washing machines and dishwashers are much more power-hungry than anything that was around when the old fuse boards were first installed. Your new fuse board will be fitted with sufficient breakers to cope with these elevated power demands within your property, with each circuit being protected more effectively than ever before.
Fuse board changing is a relatively straightforward task that can generally be done within a few hours depending on the number of circuits in your property, and the complexity of the wiring currently in place. The change can only legally be effected by a qualified electrician who is Part P registered.  It is necessary when changing a fuse board to ensure that the earth-bonding arrangements in your property meet current standards, and are upgraded if required. The fuse board replacement cost will vary according to your requirements, but is not as expensive as you may imagine, and it’s a small price to pay for your security.
At Westend glasgow Electricians we have been providing electrical services to domestic and commercial clients in South London for over 20 years. Customers looking for an Emergency Electrician in partick, a fuse board change in Bromley, or a new plug socket in glasgow know that engaging the services of our team of experts will deliver fast, efficient and professional results, every time.

Wednesday 10 April 2013

British General Consumer Unit

http://www.amazon.co.uk/gp/offer-listing/B009US0GC0

Consumer Unit 17th Edition




  • 100A Main Switch
  • 2 x 63A RCDs
  • 10 x MCBs (3 x 6A
  • 2 x 16A
  • 4 x 32A
  • 1 x 40A)
  • 3 Spare Ways
  • Modern Stylish Design with Curved Smooth Profile
  • Designed for Fast Installation
  • Integral Spirit Level
  • Easy Fit & Easy Clean Cover
  • Backed Out & Retained Terminal Screws
  • View more information
Product contents:
Consumer unit, 100A main switch, 2 x 63A 30mA RCDs, 3 x 6A MCBs, 2 x 16A MCBs, 4 x 32A MCBs, 1 x 40A MCB, busbar, cables and labels.
Specifications:
W x D x H: 451 x 117 x 234mm. BS EN 60439-3.











BG Consumer Units
For a BG consumer unit that's right for you, check out the Britsh General range. Consumer units are an integral part of everyday living and that's why we do our best to supply you with the best.