Monday, 6 March 2023

What is an EICR for landlords In Glasgow?

 An EICR is a thorough inspection and testing of the electrical installation in a property, including the wiring, electrical fittings, and consumer unit (fuse box). The testing is carried out by a qualified electrician who will check the installation against the current version of the UK's Wiring Regulations (BS 7671).

The testing procedure for an EICR involves the following:

  1. Visual inspection: The electrician will conduct a visual inspection of the electrical installation, looking for any obvious defects or signs of damage, such as cracked or damaged sockets, frayed wiring, or exposed cables.

  2. Dead testing: The electrician will then conduct a series of tests on the electrical installation with the power turned off. This includes checking the continuity of the earth wiring and testing the insulation resistance of the wiring.

  3. Live testing: Once the dead testing is complete, the electrician will turn the power back on and carry out a series of tests on the live electrical installation. This includes checking the polarity and earth loop impedance of the wiring, as well as testing the operation of residual current devices (RCDs) and circuit breakers.

  4. Functional testing: The electrician will also test the functionality of all electrical fixtures and fittings, such as switches, sockets, lights, and appliances. This ensures that all electrical components are working correctly and safely.

  5. Report: Once the testing is complete, the electrician will provide a detailed report that highlights any defects, damage, or safety concerns identified during the inspection. The report will also include recommendations for remedial work that may be required to bring the installation up to current safety standards.

In summary, electrical testing for an EICR involves a thorough inspection and testing of the electrical installation in a property, including a visual inspection, dead testing, live testing, functional testing, and a detailed report highlighting any defects or safety concerns. This testing ensures that the electrical installation is safe and meets current regulations, providing peace of mind for homeowners and tenants.


In the UK, there are several electrical tests that need to be carried out in a home to ensure that the electrical installation is safe and meets current safety standards. These tests include:

  1. Electrical Installation Condition Report (EICR): This is a comprehensive inspection and testing of the electrical installation in a property, including the wiring, electrical fittings, and consumer unit (fuse box). It is recommended that an EICR is carried out at least every 10 years for owner-occupied homes and every 5 years for rented properties.

  2. Portable Appliance Testing (PAT): This is a test of portable electrical appliances in a property, such as laptops, TVs, and kitchen appliances. It is recommended that PAT testing is carried out annually in rented properties and as required in owner-occupied homes.

  3. RCD Testing: Residual Current Devices (RCDs) are safety devices that protect against electric shock. It is recommended that RCDs are tested every 3 months in rented properties and annually in owner-occupied homes.

  4. Smoke Detector Testing: Smoke detectors are essential safety devices that can save lives in the event of a fire. It is recommended that smoke detectors are tested monthly and replaced every 10 years.

  5. Carbon Monoxide Detector Testing: Carbon Monoxide (CO) is a poisonous gas that can be produced by faulty gas appliances. It is recommended that CO detectors are tested monthly and replaced every 5-7 years.

It is important to note that these are minimum recommendations, and some situations may require more frequent testing or additional tests. It is also important to have all electrical work carried out by a qualified electrician and to keep all electrical certificates and test reports up to date.

18th Edition Consumer units in Scotland

 The 18th edition of the Wiring Regulations (BS 7671) was introduced in 2018 and includes new requirements for consumer units, also known as fuse boxes. Consumer units are the point at which the electrical supply enters a property and are responsible for distributing the electricity to the various circuits within the home. It is important to have a new 18th edition consumer unit installed in your house for a number of reasons, including safety, compliance with regulations, and future-proofing.

  1. Safety The most important reason to have a new 18th edition consumer unit installed in your house is safety. Older consumer units may not provide adequate protection against electric shocks or fires. The 18th edition of the Wiring Regulations requires consumer units to have an RCD (Residual Current Device) installed for every circuit. An RCD is a safety device that quickly switches off the electricity if it detects a fault or current imbalance. This provides a high level of protection against electric shocks and reduces the risk of electrical fires.

  2. Compliance with regulations Another reason to have a new 18th edition consumer unit installed in your house is to comply with current regulations. The 18th edition of the Wiring Regulations is a legal requirement and failure to comply could result in legal action being taken against you. Additionally, if you are selling your house, you will need to provide an Electrical Installation Condition Report (EICR) which shows that your electrical installation meets the 18th edition requirements.

  3. Future-proofing Having a new 18th edition consumer unit installed in your house will future-proof your electrical installation. The 18th edition requirements are designed to provide a high level of safety and protection, and having a new consumer unit installed now will ensure that your installation meets the latest standards for years to come. This will also save you money in the long run, as you will not need to upgrade your consumer unit every time the regulations are updated.

In conclusion, it is essential to have a new 18th edition consumer unit installed in your house for safety, compliance with regulations, and future-proofing. Failure to do so could result in serious consequences, including the risk of electric shock or fire, legal action, and the need to pay for costly upgrades in the future.

EICR WESTEND GLASGOW

Sunday, 13 February 2022

New Smoke and heat alarm legislation in Scotland

The new Smoke and heat alarms that used to be law in Scotland for landlord has now been extended to homeowners, as of February 2022 all homes in Scotland would need to be fitted with interlinked smoke and heat alarm detection systems. Below is a video from the Scottish Government regarding the new law

To request a visit from our leading installers contact WES Electrical below

WES Electrical - 01418405236 are fully qualified to install the new smoke and heat alarms

Two types of alarms

You can use either sealed battery alarms or mains-wired alarms.

Both types of alarm are interlinked by radio frequency and do not need WiFi.

What the alarms must have

If you use battery alarms, they must be sealed tamper-proof units and have long-life lithium batteries, which can be up to 10 years. You may be able to fit these types of alarms yourself and they do not need an electrician.

Mains-wired alarms are cheaper but if you use them, they must be fitted by a qualified electrician and must be replaced every 10 years. You may also need to redecorate after fitting them.

If you also need a carbon monoxide alarm and it is battery-operated, it must have a sealed battery for the duration of its lifespan.

Where and what to buy

There is no list of approved suppliers or fitters. You can buy both types of alarms online or in store from a number of retailers, and any qualified electrician can fit the mains-wired type. 

You need to check that each alarm complies with the following standards:

  • smoke alarms                       BS EN14604:2005
  • heat alarms                           BS 5446-2:2003
  • carbon monoxide detector British Kitemark EN 50291-1

More information on the standard, including the types of alarms, is in the Tolerable Standard Guidance Chapters 16 and 17.

Please note that the Nest Protect System will not meet the standard. This is because they do not meet the requirements for a heat alarm under the relevant British Standard. British Standard (BS 5839-6:2019) states that only heat alarms should be installed in kitchens.

Frequently asked questions

The more detailed information below may help to answer some other common questions about the new standard.

Cost of alarms and financial help

Homeowners and landlords

Any costs will be the responsibility of home owners and landlords, and will depend on what you currently have in place and the alarms you choose to install. We estimate that the cost for an average three bedroom house which requires three smoke alarms, one heat alarm and one carbon monoxide detector will be around £290. This is based on using the type of alarms that you can install by yourself without the need for an electrician.

The Scottish Government has, over the period 2018-20, provided the Scottish Fire and Rescue Service (SFRS) with £1m funding to install these alarms in the homes of people assessed to be at high risk from fire as part of a home fire safety visit.

As a general principle, home owners must pay for any ongoing work needed on their own property. As with other housing standards, the homeowner must meet the new fire and carbon monoxide alarm standard. Local authorities have broad discretionary powers to provide advice and help to home owners with work needed to look after their homes.

Help with the costs for pensioners and disabled people

We are providing funding through Care and Repair Scotland to help elderly and disabled people meet the new standard.

To be eligible for support from Care and Repair Scotland you must own and live in your home that  has a council tax banding of A-C and:

  • be of state pension page and receiving guaranteed Pension Credit, or
  • have a disability and be in a support group for Employment and Support Allowance

Tenants of local authority or housing associations

Social landlords (local authority and housing association landlords) are aware of the new standard and have been working to ensure that the new alarms are in place, where needed. The Scottish Government has made over £15m of loan funding available for social landlords ensuring that social tenants are safe in their homes. The standard will be monitored by the Scottish Housing Regulator, which may intervene as they deem appropriate for any non-compliance.

Shared ownership (housing association)

For shared ownership properties, as with other condition standards, responsibilities are set out in the occupancy agreement. However, in general, it is your responsibility as the proportion owner, rather than the registered social landlord, to meet the new fire and smoke alarm standard.

Private rented property 

The new standards for fire and smoke alarms extend those which currently apply in the Private Rented Sector (PRS) to housing of all tenures, your landlord should already be complying. 

Specialist alarms

If specialist alarms are needed – such as for deaf people or Telecare systems – these must be fitted in addition to any smoke, heat and carbon monoxide alarms.

Interlinked smoke and heat alarms are required to be installed in addition to any Telecare smoke/heat alarms to help keep you safe. If you have fitted or are planning to fit interlinked smoke and heat alarms, please do not remove your telecare smoke, heat or carbon monoxide alarms.  

Tenements and blocks of flats

Different homes in a shared property like a tenement or block of flats do not need to be linked to each other, and there is no need for alarms to be fitted in communal areas such as entry halls and stairways.

Asbestos in ceilings and how it affects installation

It is not necessary to disturb asbestos to install fire alarms. You may wish to seek specialist advice but it is possible to install interlinked, tamper proof long-life lithium battery alarms to ceilings with asbestos using a firm adhesive. It is unlikely that attaching an alarm with an adhesive pad would constitute disturbance of asbestos as it does not require cutting or drilling or similar intrusion to release fine particles.

If for any reason, it is inappropriate or you do not want to use an adhesive pad, battery-operated alarms that meet the manufactures requirement and can be wall mounted may be used, - to be compliant with the legislation, an alarm on the wall should be within 30 cm of the ceiling.

Replaceable batteries

Replaceable batteries cannot be used because the sensors in the alarm degrade over time and so will not be able to detect heat or smoke. This is why the alarm has a limited lifetime.  There have been several tragedies over the years where alarms failed because their batteries expired or people have removed them. Any alarm you buy will have information on how long it lasts, which can be up to 10 years.  

Sealed, tamper-proof battery units must be used because they are safer than those which allow the user to change the batteries.

Disposing of your old alarms

Some but not all types of alarms can be recycled at recycling centres. Look on the alarm for information, or check with the manufacturer.

Compliance with the new standard 

Compliance checks

Most home owners want to make their homes as safe as possible and compliance will in time form part of any Home Report when they come to sell their home.

As this will be a minimum standard for safe houses, local authorities will be able to use their statutory powers to require owners to carry out work on substandard housing. However, as is the case for other elements of the Tolerable Standard, any intervention must be proportionate, rational and reasonable and where owners are unable to meet the standard, it is not a criminal offence.

Information and advice  

Free Home Fire Safety visits from the Scottish Fire and Rescue Service (SFRS)

To protect the most vulnerable, the Scottish Fire and Rescue Service (SFRS) will only fit interlinked alarms into owner-occupied homes where the individual/household is assessed as “high risk” through our Home Fire Safety Visit assessment process.

If the individual / household does not meet these criteria, SFRS staff will provide safety advice, information and details of the revised legislation during the visit. Interim detection can also be supplied if the property has no detectors at present.

Household insurance

Different home insurance policies will have different terms and conditions which a homeowner must comply with in order for their home insurance to be valid.  If you are not sure how the new fire and smoke alarm requirements affect your policy, get in touch with your insurer to find out.

Building regulations requirements

New home extensions and building regulation requirements

While building regulations recommend mains operated devices with battery back-up for building work in certain circumstances, tamper proof long-life lithium battery operated devices may be the preferred option for home owners. 

The building standards system gives the local authority verifier a degree of flexibility when applying the building regulations to alterations, extensions and conversions. They can consider that a sealed long-life battery operated system that is interlinked via radio frequency can provide an equal or in some cases, higher level of protection than is required through Building Regulations.

A building warrant is sometimes required for the installation of fire and CO alarms

If you are only installing battery operated alarms a building warrant is not required. 


Monday, 5 April 2021

Electrical Boilers in Glasgow

What are electric boilers?

Electric boilers are a method of heating hot water for your heating system using only electricity. A typical boiler uses gas to heat the water, whilst an electric boiler can be used in off-grid areas, or where a gas supply is either not wanted or not possible. This a new method of creating hot water and a new installation of the boiler unit would need to be carried out.


Landlord Certificate?

You would initially need to carry out checks to see what electrical system you have in your property, This would involve an EICR report carried out on your property, if you are a landlord in Glasgow you would be used to this by way of yearly landlord certificates that you would require. As long as you have modern wiring, and unto date consumer unit / fuseboard the installation can go ahead without additional works required.



Landlord Certificates Glasgow

How do electric boilers work?

The boiler itself is very simple. It can come in various shapes and forms, but typically you will see a unit that has the water running through it, being heated via a heating element, just like you would a kettle. You will sometimes see long slim units that are designed to create maximum surface area to heat the water.

What are the advantages of electric boilers?

Electric boilers can be advantageous in certain situations. They are very simple pieces of technology, so they don’t need a lot of space, and can be placed almost anywhere in a property because they don’t need a flue or a gas pipe run to them. Very little heat is lost in the process of heating the water, so electric boilers are almost 100% efficient.

They tend to be easier to install and they obviously don’t need a Gas Safe engineer. The simplicity of the system and the installation process means that the overall cost of installation is going to be much less than a gas boiler.

What are the disadvantages of electric boilers?

Of course, if electric boilers were the best solution, you would see them everywhere, but you don’t. There are downsides to electric boilers – let me run you through the key points. Gas is considerably cheaper than electricity, at about 30% of the price. That means the cost of heating water using electricity is going to be a lot higher, even if you have a very efficient system.

That much is fairly obvious, but even when you compare electric boilers to other forms of electric heating, the electric boiler doesn’t necessarily come out on top. If you compare it to infrared, for example, an electric boiler will be more expensive to run.

Electric boilers probably have their place in certain properties. They are a simple, easy-to-install option but for many people there are going to be better ways to heat the home out there to look at. If gas isn’t an option, infrared, heat pumps or even oil boilers are all likely to be cheaper to run than electric boilers.


Landlord Certificates Glasgow

Tuesday, 30 March 2021

Landlord Safety

1. Introduction

The majority of landlords are proactive when it comes to ensuring the safety of their tenants and make a welcome contribution to the housing market. But a minority fail to do so, putting their tenants in danger as a result.

These new Regulations require landlords in Glasgow to have the electrical installations in their properties inspected and tested by a person who is qualified and competent, at least every 5 years. Landlords have to provide a copy of the electrical safety report to their tenants, and to their local authority if requested.

This means that all landlords now have to do what good landlords already do: make sure the electrical installations in their rented properties are safe.

The Regulations came into force on 1 June 2020 and form part of the Department’s wider work to improve safety in all residential premises and particularly in the private rented sector.

This is a major step towards levelling up the private rented sector, making sure it will offer high-quality, safe and secure housing. Along with our social and owner-occupied sectors, this is housing this country deserves.

This government values the contribution made by good landlords, the majority of whom provide well maintained, safe, secure and high-quality places to live, work and raise families.

Read the Regulations.

Read the Explanatory Memorandum to the Regulations.

2. What do the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 require?

Landlords of privately rented accommodation must:

  • Ensure national standards for electrical safety are met. These are set out in the 18th edition of the ‘Wiring Regulations’, which are published as British Standard 7671.
  • Ensure the electrical installations in their rented properties are inspected and tested by a qualified and competent person at least every 5 years.
  • Obtain a report from the person conducting the inspection and test which gives the results and sets a date for the next inspection and test.
  • Supply a copy of this report to the existing tenant within 28 days of the inspection and test.
  • Supply a copy of this report to a new tenant before they occupy the premises.
  • Supply a copy of this report to any prospective tenant within 28 days of receiving a request for the report.
  • Supply the local authority with a copy of this report within 7 days of receiving a request for a copy.
  • Retain a copy of the report to give to the inspector and tester who will undertake the next inspection and test.
  • Where the report shows that remedial or further investigative work is necessary, complete this work within 28 days or any shorter period if specified as necessary in the report.
  • Supply written confirmation of the completion of the remedial works from the electrician to the tenant and the local authority within 28 days of completion of the works.

3. Which rented properties do the Electrical Safety Regulations apply to?

The regulations came into force on 1 June 2020, they apply to new tenancies from 1 July 2020 and existing tenancies from 1 April 2021. The relevant date for determining when the new requirements apply is the date on which the tenancy is granted. A new tenancy is one that was granted on or after 1 June 2020.

You may wish to seek advice if you are not clear on which date a tenancy was granted. Shelter and Citizen’s Advice provide advice on their websites.

If a private tenant has a right to occupy a property as their only or main residence and pays rent, then the Regulations apply. This includes assured shorthold tenancies and licences to occupy.

See guidance on tenancy types.

Exceptions are set out in Schedule 1 of the Regulations and include social housing, lodgers, those on a long lease of 7 years or more, student halls of residence, hostels and refuges, care homes, hospitals and hospices, and other accommodation relating to healthcare provisions.

4. What about Houses in Multiple Occupation (HMOs)?

A house in multiple occupation (HMO) is a property rented out by at least 3 people who are not from one ‘household’ (for example a family) but share facilities like the bathroom and kitchen. If an HMO is a tenant’s only or main residence and they pay rent, then these Regulations apply to the HMO.

The Management of Houses in Multiple Occupation (England) Regulations 2006 previously put specific duties on landlords around electrical safety. This requirement has now been repealed, and HMOs are now covered by the new Electrical Safety Regulations.

HMOs with 5 or more tenants are licensable. The Housing Act 2004 has been amended by these Regulations to require a new mandatory condition in HMO licences ensuring that every electrical installation in the HMO is in proper working order and safe for continued use. See guidance on HMO licences. 

5. The inspection

How do I find a ‘qualified and competent person’ to carry out the test?

The Regulations require landlords to have the electrical installations in their properties inspected and tested by a person who is qualified and competent, at least every 5 years.

Guidance has been produced by the electrical safety industry that covers how landlords can choose a qualified and competent inspector and tester. This includes, but is not limited to:

  • Electrical Safety Roundtable
  • Registered Competent Person Electrical single mark and register

The electrical safety industry has established competent person schemes. Membership of these will not be compulsory to ensure there is no further pressure placed on the industry, nor undue burden placed on inspectors and testers.

When commissioning an inspection, in order to establish if a person is qualified and competent landlords can:

  • check if the inspector is a member of a competent person scheme; or
  • require the inspector to sign a checklist certifying their competence, including their experience, whether they have adequate insurance and hold a qualification covering the current version of the Wiring Regulations and the periodic inspection, testing and certification of electrical installations.

What standard should the electrical installation meet?

The standards that should be met are set out in the 18th edition of the Wiring Regulations.

The Regulations state that a landlord must ensure that electrical safety standards are met, and that investigative or remedial work is carried out if the report requires this.

The electrical installation should be safe for continued use. In practice, if the report does not require investigative or remedial work, the landlord will not be required to carry out any further work.

What will be inspected and tested?

The ‘fixed’ electrical parts of the property, like the wiring, the socket-outlets (plug sockets), the light fittings and the consumer unit (or fuse box) will be inspected. This will include permanently connected equipment such as showers and extractors.

What will happen in the inspection?

The inspection will find out if:

  • any electrical installations are overloaded
  • there are any potential electric shock risks and fire hazards
  • there is any defective electrical work
  • there is a lack of earthing or bonding – these are 2 ways of preventing electrical shocks that are built into electrical installations

What about electrical appliances like cookers, fridges, televisions etc?

The Regulations do not cover electrical appliances, only the fixed electrical installations.

We recommend that landlords regularly carry out portable appliance testing (PAT) on any electrical appliance that they provide and then supply tenants with a record of any electrical inspections carried out as good practice.

Tenants are responsible for making sure that any of their own electrical appliances are safe.

See guidance on portable appliance testing (PAT).

Tenants and landlords may consider registering their own electrical appliances with a product registration scheme. 

6. The report

Landlords must obtain a report (usually an Electrical Installation Condition Report or EICR) from the person conducting the inspection and test which explains its outcomes and any investigative or remedial work required.

Landlords must then supply a copy of this report to the tenant within 28 days of the inspection and test, to a new tenant before they occupy the premises, and to any prospective tenant within 28 days of receiving a request for the report.

If a local authority requests it, landlords must supply them with a copy of this report within 7 days of receiving the request.

If the report requires remedial work or further investigation, landlords must provide written confirmation that the work has been carried out to their tenant and to the local authority within 28 days of completing the work.

Landlords must retain a copy of the report to give to the inspector and tester who will undertake the next inspection and test.

What will the report show?

The electrical installation should be safe for continued use. In practice, if the report does not require investigative or remedial work, the landlord will not be required to carry out any further work.

Inspectors will use the following classification codes to indicate where a landlord must undertake remedial work.

  • Code 1 (C1): Danger present. Risk of injury. The electrical inspector may make any C1 hazards safe before leaving the property.
  • Code 2 (C2): Potentially dangerous.
  • Further Investigation (FI): Further investigation required without delay.
  • Code 3 (C3): Improvement recommended. Further remedial work is not required for the report to be deemed satisfactory.

If codes C1 or C2 are identified in on the report, then remedial work will be required. The report will state the installation is unsatisfactory for continued use.

If an inspector identifies that further investigative work is required (FI), the landlord must also ensure this is carried out.

The C3 classification code does not indicate remedial work is required, but only that improvement is recommended. Landlords don’t have to make the improvement, but it would improve the safety of the installation if they did.

What about new build properties or new electrical installations?

If a property is newly built or has been completely rewired, it should have an Electrical Installation Certificate known as an EIC.

Landlords can provide a copy of the EIC to tenants and, if requested, the local authority. The landlord will then not be required to carry out further checks or provide a report for 5 years after the EIC has been issued, as long as they have complied with their duty or duties under the Regulations.

7. Remedial work

If the report shows that remedial work or further investigation is required, as set out above, landlords must complete this work within 28 days or any shorter period if specified as necessary in the report. Landlords must then provide written confirmation that the work has been carried out to their tenant and to the local authority within 28 days.

What if I don’t do the remedial work?

If a local authority has reasonable grounds to believe that a landlord is in breach of one or more of the duties in the Regulations, they must serve a remedial notice on the landlord requiring remedial action.

Should a landlord not comply with the notice, the local authority may arrange for remedial action to be taken themselves.

The local authority can recover the costs of taking the action from the landlord. The landlord has the right of appeal against a demand for costs.

What if a tenant won’t let me in, or I can’t find an inspector?

A landlord is not in breach of their duty to comply with a remedial notice, if the landlord can show they have taken all reasonable steps to comply.

A landlord could show reasonable steps by keeping copies of all communications they have had with their tenants and with electricians as they tried to arrange the work, including any replies they have had. Landlords may also want to provide other evidence they have that the installation is in a good condition while they attempt to arrange works. This could include the servicing record and previous safety reports.

Urgent remedial action

If the report indicates that urgent remedial action is required, and the landlord has not carried this out within the period specified in the report, the local authority may with the consent of the tenant arrange to carry out remedial work.

The local authority must authorise a qualified and competent person in writing to undertake the remedial action and give at least 48 hours’ notice to the tenant.

The costs for carrying out the remedial work can be recovered from the landlord.

Financial penalties

Local authorities may impose a financial penalty of up to £30,000 on landlords who are in breach of their duties.

Can I appeal against local authorities serving a notice, taking remedial action or a financial penalty?

Yes, landlords can appeal against the decision of a local authority.

In the first instance, landlords have 21 days to make written representations to a local authority against a remedial notice and the intention to impose a financial penalty. The remedial notice is suspended until the local authority considers representations. The local authority must inform the landlord of their decision within 7 days.

Landlords then have a right of appeal to the First-tier Tribunal against:

  • The decision to take remedial action by the local authority. An appeal must be made within 28 days from the day on which a remedial notice is served.
  • A demand for the recovery of costs made by the local authority following remedial action.
  • The decision to take urgent remedial action by the local authority. An appeal must be made within 28 days from the day on which the work started.
  • A financial penalty.

Appeals are made to the First-tier Tribunal (Property Chamber). See more information on the First-tier Tribunal (Property Chamber).

8. Further questions

What if a tenant won’t let me in, or I can’t find an inspector?

A landlord is not in breach of their duty to comply with a remedial notice, if the landlord can show they have taken all reasonable steps to comply.

A landlord could show reasonable steps by keeping copies of all communications they have had with their tenants and with electricians as they tried to arrange the work, including any replies they have had. Landlords may also want to provide other evidence they have that the installation is in a good condition while they attempt to arrange works. This could include the servicing record and previous safety reports.

If an inspection took place and a satisfactory report was issued before the 18th edition of the Wiring Regulations came into force, but less than 5 years ago, will a landlord always need to have the property inspected again as soon as the Electrical Safety Regulations come into force?

Regulation 3 requires that landlords have the electrical installation inspected and tested at intervals of no longer than every 5 years. Electrical safety standards (the 18th edition of the Wiring Regulations) must be met throughout the period of that tenancy.

The 18th edition of the Wiring Regulations came into effect in 2019, so if a landlord already has a report for a property that was carried out after this date and has complied with all the other requirements of the Regulations, they won’t have to have another inspection for 5 years, provided the report does not state that the next inspection should take place sooner.

Existing installations that have been installed in accordance with earlier editions of the Wiring Regulations may not comply with the 18th edition in every respect. This does not necessarily mean that they are unsafe for continued use or require upgrading.

It is good practice for landlords with existing reports to check these reports and decide whether the electrical installation complies with electrical safety standards. Landlords might also wish to contact the inspector who provided a report to ensure the installation complies with electrical safety standards.

Will all installations have to comply with the 18th edition, even if they were installed before this edition was in force?

The Regulations state that a landlord must ensure that electrical safety standards are met, and that investigative or remedial work is carried out if the report requires this.

The electrical installation should be safe for continued use. In practice, if the report does not require investigative or remedial work, the landlord will not be required to carry out any further work.

Reports can also recommend improvement, in addition to requiring remedial work. If a report only recommends improvement but does not require any further investigative or remedial work to be carried out – indicated with a ‘C3’ classification code – then while it would be good practice to carry out this work, it would not be required to comply with the Regulations.

What about new build properties or new installations?

If a property is newly built or has been completely rewired, it should have an Electrical Installation Certificate known as an EIC.

Landlords can provide a copy of the EIC to tenants and, if requested, the local housing authority. The landlord will then not be required to carry out further checks or provide a report for 5 years after the EIC has been issued, as long as they have complied with their duty or duties under the Regulations.

Which tenancies do the new Regulations apply to?

If a private tenant has a right to occupy a property as their only or main residence and pays rent, then the Regulations apply. This includes assured shorthold tenancies and licences to occupy.

What about where tenancies ‘roll over’ into periodic tenancies? Will that count as a new tenancy?

Whether or not a ‘periodic’ tenancy is a new tenancy, as defined in Regulation 2, depends on the type of tenancy issued.

  • For ‘contractual periodic tenancies’ – where it is written in the original tenancy agreement that on expiry of the fixed term the tenancy will become periodic – the periodic tenancy will be part of the same tenancy and no new tenancy will be created.
  • For ‘statutory periodic tenancies’ – where on expiry of the fixed term the tenancy rolls over into a periodic tenancy automatically by statute (rather than by contract) – the periodic tenancy will be a new tenancy.

Properties let on statutory periodic tenancies where the fixed term expires between July 2020 and April 2021 will require an inspection and test at this point under the Regulations.

Landlord Certificates Glasgow


WES Electrical -Understanding EICR and EPC Certificates in Glasgow: A Complete Guide for Property Owners 2024

  Understanding EICR and EPC Certificates in Glasgow : A Complete Guide for Property Owners If you’re a property owner or landlord in Glasgo...